 PLP75 AC-DC Series Data Sheet 75 Watts
Features * * * * * * * * * * *
RoHS compliant for all six substances 75 Watts with 5 CFM forced-air cooling Typical 80% efficiency 65 Watts with convection cooling 85-264 VAC wide-range input FCC & CISPR 22, Class "B" - Conducted EMI Power Factor Corrected (meets IEC61000-3-2) Typical 0.99 power factor Height meets 1U chassis constraints Two-year limited warranty Safety Agency pending to UL60960-1, CSA 22.2No. 60950-1-03, and TUV EN60950/IEC 60950-1 * Compliance with EN 61000-4-2 level 4 (ESD), EN 61000-4-3 (RF), EN 61000-4-4 level 3 (Fast Transient/Burst), EN 61000-4-5 class 3 (Surge)
Applications * * * * * *
Telecom, datacom Networking Industrial Medical instrumentation Consumer Gaming
Description The PLP75 is a cost-effective and efficient series of AC-DC power supplies suited for telecom, datacom, and many other applications. The PLP75 Series meets the international information technology safety standards with the CEMark for the European Low Voltage Directive (LVD). Active power-factor-correction (PFC) is a standard feature. PFC enables the user to comply with EN 61000-3-2 line harmonics requirements. In addition, PFC reduces line losses and rms input current to help achieve low-cost operation and makes the end product more environmentally friendly to the end users.
Single-Output Model Selection
Model Nominal Output Voltage (VDC)
3.3 5 12 24 48
5 5 5 5 5
Min-Max Output Current (Amps), Convection
0.2 - 13 0.2 - 13 0.1 - 5.4 0.1 - 2.7 0.1 - 1.4
Min-Max Output Current (Amps), 1 Forced Air
0.2 - 15 0.2 - 15 0.1 - 6.5 0.1 - 3.1 0.1 - 1.6
Peak Output Current 2 (Amps)
17.5 16.5 7 3.5 1.8
Total Regulation 3 (%)
2 2 2 2 2
Ripple & Noise 4 pk-pk %
1 1 1 1 1
PLP75-1003G PLP75-1005G PLP75-1012G PLP75-1024G PLP75-1048G
1
5 CFM or 150 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm cross-sectional area) with power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC side to the DC side. 2 Peak current duration for less than 30 seconds with a maximum duty cycle of 10%. 3 At 25 C ambient including voltage set point tolerance, line and load regulation 4 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 5 Output is adjustable 10 % of nominal.
DEC 04, 2006 revised to JAN 30, 2007
Page 1 of 6
www.power-one.com
PLP75 AC-DC Series Data Sheet 75 Watts
Triple-Output Model Selection
Model Nominal Output Voltage (VDC)
+3.3 +5 PLP75-3301G +12 +3.3 +12 -12 PLP75-3000G +5
5 5 5 5
Min-Max Output Current (Amps), Convection
0.2 - 7.5 0.3 - 3 0.0 - 0.7 0.2 - 7.5 0.3 - 3 0.0 - 0.7 0.2 - 7.5 0.3 - 3 0.0 - 0.7 0.2 - 7.5 0.3 - 2.4 0.0 - 0.7 0.2 - 7.5 0.3 - 2 0.0 - 0.7
Min-Max Output Current (Amps), 1 Forced Air
0.2 - 8 0.3 - 4 0.0 - 1 0.2 - 8 0.3 - 4 0.0 - 1 0.2 - 8 0.3 - 4 0.0 - 1 0.2 - 8 0.3 - 3.2 0.0 - 1 0.2 - 8 0.3 - 2.6 0.0 - 1
Peak Output Current 2 (Amps)
10 4.6 1.5 10 4.6 1.5 10 4.6 1.5 10 3.7 1.5 10 2.6 1.5
Total Regulation 3 (%)
2 2 5 2 5 5 2 5 5 2 5 5 2 5 5
Ripple & Noise 4 pk-pk %
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
PLP75-3300G
+12 -12 PLP75-3003G +5
5
+15 -15 PLP75-3001G +5
5
+24 -12
1
CFM or 150 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm cross-sectional area) with power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC side to the DC side. 2 Peak current duration for less than 30 Sec with a max duty cycle of 10%. 3 At 25 C ambient including voltage set point tolerance, line and load regulation. 4 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 5 Output is adjustable 10 % of nominal.
ELECTRICAL SPECIFICATIONS Input Specifications
Parameter AC Input Voltage Range DC Input Voltage Range Frequency Power Factor Input current Inrush current Input fuse Efficiency Conditions/Description Continuous voltage range Continuous voltage range; For input above 250 VDC, consult factory. AC Input Complies with EN61000-3-2 Standard for Line Current Harmonics 85 VAC at 75 W 115 VAC, Max power, 25 C 230 VAC, Max power, 25 C Non-user serviceable internally located AC input line fuse is provided. At maximum output power, nominal line 1.5 16 32 2.5 80 Amps rms A pk A pk A % Min. 85 120 47 Nom. 100 - 250 170 50 - 60 Max. 264 250 63 Units VAC VDC Hz
DEC 04, 2006 revised to JAN 30, 2007
Page 2 of 6
www.power-one.com
PLP75 AC-DC Series Data Sheet 75 Watts
Output Specifications
Parameter Output power Output DC voltages Conditions/Description With convection cooling With 5 CFM forced-air cooling Vo1 is adjustable 10% of nominal. Vo2 is adjustable 10% of nominal on PLP753300G. Vo3 is not adjustable. Min. Nom.
1
Max.
Units Watts
1
VDC
1
Output DC current Minimum load Output ripple & noise CM noise Overshoot Load transient Turn-On & Turn-Off characteristics Turn-on time from AC ON Turn-on Delay Hold-up Time Vo1 overshoot at turn-on Vo1 deviation due to a 50 to 100% load change at a rate of 1A/s Outputs turn ON monotonically. Time required for output within regulation after initial application of AC input. Tme required for output voltage to rise from 10% to 90%. Time Vo1 is required to stay within 95% regulation after removal of AC measure from the last peak of the AC line at 115 VAC. Not available. Phase margin. Gain margin.
1
A A mV pk-pk mV pk-pk % %
No damage occurs to the power supply when operating at zero load.
1
1
50 3 3
0.2 0.2 20
1.5 20
Sec ms ms
Remote Sense Control loop stability
45 10
Degrees dB
See Model Selection tables.
Fault Protection
Parameter Current Limit set point Conditions/Description Overload protected - power limit. Min. Nom. Max. 145 Units % of peak rating
Short-circuit protection OVP Trip
Provided on all outputs. Vo1, Vo2 115 125 135 % of set point
DEC 04, 2006 revised to JAN 30, 2007
Page 3 of 6
www.power-one.com
PLP75 AC-DC Series Data Sheet 75 Watts
Isolation Requirements
Parameter Input-to-Chassis Input-to-Output Output-to-Chassis Output-to-Output
1
Conditions/Description
Min. 2121 4242 500
1
Nom.
Max.
Units VDC VDC VDC
All outputs share the same common.
EMC Immunity
Parameter ESD RF Susceptibility Fast Transient/Burst Surge RF Immunity Magnetic Fields Voltage Interruptions Conditions/Description EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6. EN 61000-4-8. EN 61000-4-11. Level 4. Level 3. Level 3. Class 3.
EMC Emmisions
Parameter FCC Part 15 CISPR 22 and CISPR 11 Conditions/Description Conducted Class B, Radiated Class A. Conducted Class B, Radiated Class A.
Environmental Specifications
Parameter Cooling Audible Noise Operating Temp 0 C to 70 C with linear derating to 50% above 50 C. Unit will start-up at -20 C, but will not meet all published specifications. Operating. Non-Operating. -40 95% relative humidity @ 40 C, non-condensing Operating: Random vibration; 5 to 500 Hz (10 minutes, each axis). Non-Operating: Random vibration; 5 to 500 Hz (10 minutes, each axis). Shock Operating: half-sine, 11 3 ms, 3-axis. Non-Operating: half-sine, 11 3 ms, 3-axis. 2.4 Grms -20 50 Conditions/Description Rated for convection and forced-air cooling. 0 70 dBA C Min. Nom. Max. Units
Altitude Storage Temp Humidity Vibration
10K 50K 85
ASL ft ASL ft C
6 15 40
Grms G G
DEC 04, 2006 revised to JAN 30, 2007
Page 4 of 6
www.power-one.com
PLP75 AC-DC Series Data Sheet 75 Watts
Regulatory & Safety Approvals
Parameter UL60950-1 CSA-C22.2, No. 60950-1-03 EN 60950-1 /IEC 60950-1 CE Mark for LVD CB Approval Ground Leakage Current Conditions/Description All single-output models are approved. Tripleoutput models are pending. All single-output models are approved. Tripleoutput models are pending. All single-output models are approved. Tripleoutput models are pending. All single-output models are approved. Tripleoutput models are pending. Completed for single-output models. Pending for triple-output models. At 230 VAC. 1.4 mA Min. Nom. Max. Units
Mechanical Specifications
Parameter Dimensions Length Width Height, including component or component lead protrusion on the bottom of the PCB. Power Density Mounting Input Ground connector for plastic chassis Output Outline Drawing Pins/Functions Weight Mounting distance Optional Accessories Note
1
Conditions/Description
Min.
Nom.
Max. 127 76.2 35 4
Units mm mm mm W/cu in
With forced-air cooling. (Location/Hardware); see Outline Drawing. (Location/Connector); J1 - Molex 26-62-4030 or equivalent. Provided. (Location/Connector); J2 - Molex 26-60-4060 or equivalent. See Mechanical Drawing. 0.36 0.113
kg in
Bracket, enclosure with IEC connector and switch, and cover options are offered. Consult factory for details.
The minimum distance from the bottom of the component leads (solder side) or top of the components (component side) to the customer's metal chassis should be at least 0.113 " (2.85 mm).
1
DEC 04, 2006 revised to JAN 30, 2007
Page 5 of 6
www.power-one.com
PLP75 AC-DC Series Data Sheet 75 Watts
J1 - AC CONN. Pin 1 NEUTRAL missing pin LINE
Mechanical Drawing
5.00 +/- 02 4.55 safety ground connection point Pin #1 O 0.16 (4 places)
Pin 2 Pin 3
J2 - DC CON (-1xxx models) Pin 1* Pin 2 Vo1 Vo1 Vo1 DC COM DC COM DC COM
safety ground connection point
Pin 3 Pin 4
J1 input connector 3.00 +/-.02
J2 - DC output connector (see pin-out table)
Pin 5 Pin 6
J2 - DC CON (-3xxx models) 2.55 Pin #1 Pin 1 Pin 2 Vo2 Vo1 Vo1 DC COM DC COM Vo3
TOP VIEW
fastener clearance area 4 places)
Pin 3 Pin 4 Pin 5 Pin 6
0.06
1.37 +/-.02
SIDE VIEW
1.2
END VIEW
Printed Circuit Board 0.1
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
DEC 04, 2006 revised to JAN 30, 2007
Page 6 of 6
www.power-one.com


▲Up To Search▲   

 
Price & Availability of PLP75

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X